  What material thickness is Rediframe available in?
Are Rediframe available in galvanized steel?
Why are Rediframe sold by the " wall size" rather than jamb depth?
Are Rediframes available welded?
What casing (trim) options are available?
Can you have different casing on a single frame?
What is a " lance" ?
What is a " nail hole" ?

What colors are available for Rediframes?
What is the minimum wall size?
What is the maximum wall size?
Is Rediframe available with a kerf?

Are there differences between Rediframe and Kerf Rediframe?
What hinge preps are available?
What is a Universal Hinge Prep?
What strike preps are available?
What is an adjustable t-strike?
Does Rediframe have welded hinge plates like hollow metal frames?
Does Rediframe have welded strike plates like hollow metal frames?
Will a Rediframe hold a heavy door?
How can a knock-down light gage frame support heavy doors?
What is a Rediframe set number?
Are Rediframes handed?
Are Rediframes ever handed?
Does Rediframe make borrowed lites and sidelites?
Are sidelites available for 1-3/8" doors?
What is the maximum width and height for a sidelite or borrowed lite frame?
Are Rediframes fire rated?
Why does Rediframe provide embossed rather than mylar or steel labels?
Are the embossed labels valid for positive pressure as well?
How do I know which doors or intumescent material can be used with Rediframes?
Are " kerf" frames approved for positive pressure?
Are sidelite and borrowed lite frames approved for positive pressure?
What is the maximum rating for a sidelite or borrowed lite frame?
Is glazing material required on all fire-rated sidelites and borrowed lites?
Is Firelite or other specialty glass required for the positive pressure rated assemblies or 60-minute borrowed lites?
Can wood trim be used on fire-rated sidelites and borrowed lites?
What is an edge sealing system?
Do all doors require edge-sealing systems for positive pressure?
What category do doors that require edge-sealing materials fall into?
What category does Rediframe fall into?
What is the " S" label?
Are frames required to have the " S" label?
Are all " S" doors and frames 20-minute rated?
Does Rediframe offer an adjustable throat frame?
How much adjustment does Rediflex provide?
What door thickness are Rediflex frames applicable to?
Are there other differences between Rediflex and Kerf Rediflex?
Why the difference in casing?
As the wall sizes change on Rediflex, do both pieces change?
Can Rediflex be pre-hung?
What kerf weatherstrip does Rediframe provide?
Is kerf weatherstrip available for positive pressure frames?
What is the rough opening requirement for Rediframe?
What is the rough opening requirement for Rediflex?
Why use a prefinished frame?
Are reinforcements for door closers available?
Can electric strikes be used with Rediframe?
What styles of frames are Rediframes available in?
Can Rediframes be used in a masonry wall?
Why is a Rediframe in a masonry opening not as secure?
Does a custom casing void the fire rating?
What is the lead-time for Rediframe and Rediflex frames?


Q What material thickness is Rediframe available in? top
A 18, 20 or 22 gage

Q Are Rediframe available in galvanized steel? top
A Yes (A40)

Q Why are Rediframe sold by the " wall size" rather than jamb depth? top
A Rediframe has no " backbend returns" like hollow metal frames.

Q Are Rediframes available welded? top
A No, Rediframes are provided KD (knock-down) only.

Q What casing (trim) options are available? top
A Steel (standard), aluminum, S56 Steel Colonial (2-1/4" ) or prepped for wood trim (by others)

Q Can you have different casing on a single frame? top
A Yes, it is common to have steel casing on one side and wood trim on the other side.

Q What is a " lance" ? top
A The lance is an integral clip formed in the leg (face) of the frame to accept steel, aluminum or C56 casing.

Q What is a " nail hole" ?top
A A nail hole is the prep for wood trim.

Q What colors are available for Rediframes? top
A Rediframe Brown, Ivory, Bright White and Prime are available at no upcharge. Mojave Brown, Black, Lt. Grey and Tan Prime are available with a per frame charge. Rediframe can be provided in any custom color with a per frame charge. A set-up is required for orders less than (100) frames if a per frame charge is applicable.

Q What is the minimum wall size? top
A 2-5/8" for 1-3/8" frames or cased opening profiles 2-7/8" for 1-3/4" frames 4" for 1-3/8" X 1-3/4" communicating frames 4-1/2" for 1-3/4" x 1-3/4" communicating frames.

Q What is the maximum wall size? top
A 13" Wall sizes are available in 1/8" increments

Q Is Rediframe available with a kerf? top
A Yes
top

Q Are there differences between Rediframe and Kerf Rediframe? top
A Yes, Kerf Rediframe is available for 1-3/4" doors only. It is not available in sidelite, borrowed lite, communicating or cased opening applications.

Q What hinge preps are available? top
A For 1-3/8" doors: 3-1/2" x ¼" radius template hinge For 1-3/4" doors: 4" x ¼" radius template hinge 4-1/2" square template hinge (standard weight) 4" x 5/8" radius " Universal Hinge Prep" (template or non-template).

Q What is a Universal Hinge Prep?top
A The UHP is designed to accommodate multiple hinge patterns that occur on insulated steel entry doors. The hinge emboss is fixed but different hinge gussets are supplied for the various manufacturers. Each hinge gusset is numbered thus: #1 = Template hole pattern #2 = Acore Door #3 = Pease Door #5 = Therma Tru, Taylor / Perma Door, Johnson (non-template), Prem Dor (Ceco) #6 = Challenge, Prem Dor (Castlegate) #7 = Stanley Door Systems.

Q What strike preps are available?
top
A For 1-3/8" doors: 2-3/4" Adjustable T-strike For 1-3/4" doors: 2-3/4" Adjustable T-strike, 4-7/8" ASA strike, or 2-3/4" deadbolt strike.

Q What is an adjustable t-strike? top
A A two-piece strike plate that allows the door to be adjusted to eliminate the rattle.

Q Does Rediframe have welded hinge plates like hollow metal frames? top
A No, 14-gage steel gussets (plates) are applied in the factory.

Q Does Rediframe have welded strike plates like hollow metal frames? top
A No, the screw holes are extruded into the steel and self-tapping screws are used.

Q Will a Rediframe hold a heavy door?
top
A Yes, Rediframes have been cycle tested using a 22-gage frame and a 188-pound hollow metal door for 1,000,000 cycles.

Q How can a knock-down light gage frame support heavy doors? top
A The strength of the frame lies in the installation method. Rediframes sleeve the wall itself. The fasteners go through the face of the frame, through the gypsum board and into the stud. Fasteners are located approximately every 12" on the frame so a 3-0 x 6'-8 frame has roughly 34 fasteners! Once installed, the frame becomes as strong as the wall itself.

Q What is a Rediframe set number? top
A The set number identifies the door thickness, number and size of hinges and strike prep if applicable. Example: RFS 31 = 1-3/4" door with 1-1/2 pair of 4-1/2" square template hinges with either an adjustable 2-3/4" T-strike prep or 4-7/8" ASA strike prep.

Q Are Rediframes handed? top
Standard 6'-8 Rediframe with a single strike emboss are NOT handed. 7'-0 Rediframe can be provided NON-HANDED. Pair door frames are non-handed but the header will become handed if flushbolt prep is added.

Q Are Rediframes ever handed? top
A Yes, when the hinge and strikes are not symmetrical or if a deadbolt is added.

Q Does Rediframe make borrowed lites and sidelites? top
A Yes

Q Are sidelites available for 1-3/8" doors? top
A No, 1-3/4" doors only

Q
What is the maximum width and height for a sidelite or borrowed lite frame? top
A 10' x 10'

Q Are Rediframes fire rated? top
A Yes, standard 3-sided Rediframes, which meet the label parameters, are provided with an embossed 90-minute label at no charge.

Q Why does Rediframe provide embossed rather than mylar or steel labels? top
A The use of the embossed labels virtually eliminates the need for field labeling due to frames being changed after shipment or labels removed for painting.

Q Are the embossed labels valid for positive pressure as well? top
A Yes, UBC 7-2, 1994 (neutral pressure) and UBC 7-2, 1997 (positive pressure) are on the embossed label.

Q How do I know which doors or intumescent material can be used with Rediframes?
top
A The information is in the installation instructions.

Q Are " kerf" frames approved for positive pressure? top
A Yes

Q Are sidelite and borrowed lite frames approved for positive pressure? top
A Yes

Q What is the maximum rating for a sidelite or borrowed lite frame? top
A 45-minute for sidelites and 60-minute for borrowed lites

Q Is glazing material required on all fire-rated sidelites and borrowed lites? top
A No. It is required for positive pressure rated sidelites and borrowed lites as well as all 60-minute borrowed lites.

Q Is Firelite or other specialty glass required for the positive pressure rated assemblies or 60-minute borrowed lites?
A No, ¼" wire glass is approved

Q Can wood trim be used on fire-rated sidelites and borrowed lites? top
A Yes, on the perimeter of the frame as well as the mullions.

Q
What is an edge sealing system? top
A A material (intumescent) that seals the edges of the doors.

Q Do all doors require edge-sealing systems for positive pressure? top
A No. Doors that require no edge-sealing materials are classified as Category A doors.

Q
What category do doors that require edge-sealing materials fall into? top
A Category B doors.

Q What category does Rediframe fall into? top
A Category C frames - For use with Category A doors and Category B doors

Q What is the " S" label? top
A The " S" indicates a Smoke and Draft Control opening.

Q Are frames required to have the " S" label? top
A No. The door and frame assembly is covered by the " S" mark on the door label.

Q Are all " S" doors and frames 20-minute rated? top
A No

Q Does Rediframe offer an adjustable throat frame? top
A Yes, Rediflex and Kerf Rediflex

Q How much adjustment does Rediflex provide? top
A 1-1/4" on Rediflex and 1" on Kerf Rediflex.

Q What door thickness are Rediflex frames applicable to? top
A 1-3/4" only

Q Are there other differences between Rediflex and Kerf Rediflex? top
A Yes, Rediflex comes standard with snap-on steel casing. Kerf Rediflex is standard prepped for wood casing.

Q Why the difference in casing? top
A Kerf Rediflex is mainly used with residential steel entry doors. The residential market considers wood standard.

Q
As the wall sizes change on Rediflex, do both pieces change?top
A No, the base side (has hinge and strike prep) is the same profile regardless of wall size. The closure piece (" L" angle) is the only piece that changes.

Q Can Rediflex be pre-hung? top
A Yes

Q What kerf weatherstrip does Rediframe provide? top
A Schlegel QDS 500 for non-rated or neutral pressure applications

Q Is kerf weatherstrip available for positive pressure frames? top
A Yes

Q What is the rough opening requirement for Rediframe? top
A Nominal frame width + 1-1/4" (width) *Net frame height + 1" (height) **Net frame height + 1/2" (height) *For steel, aluminum or C56 casing ** For wood trim

Q What is the rough opening requirement for Rediflex? top
A Nominal frame width + 1" (width) *Net frame height + 1" (height) **Net frame height + 1/2" (height) *For steel, aluminum or C56 casing ** For wood trim

Q Why use a prefinished frame? top
A It is less expensive. You can save between $30 to $60 per frame in field painting costs

Q Are reinforcements for door closers available?
top
A Yes, reinforcing is available for parallel and regular arm closers. Reinforcing is also available for RIM hardware.

Q Can electric strikes be used with Rediframe? top
A Not at this time.

Q What styles of frames are Rediframes available in? top
A Single, Pair, Cased Opening, Pocket, Communicating and Dutch

Q Can Rediframes be used in a masonry wall? top
A Only if the opening is an interior door that does not need to be a secured door.

Q Why is a Rediframe in a masonry opening not as secure? top
A Installation in a masonry opening requires sub-bucking. Sub-bucking is a method in which 2x's are anchored to the opening at the head and jambs. This provides the material that the Rediframe is attached to. This means that the opening is only as secure as the anchors holding the 2x's to the masonry.

Q Does a custom casing void the fire rating? top
A Custom casings are done everyday, but Warnock Hersey is the only organization that can say whether your design will void the rating. Generally, this is a material issue only. Contact the factory.

Q What is the lead-time for Rediframe and Rediflex frames? top
A 3 weeks for shipping, 4th week for delivery
   